SRNE 5kW 48v Hybrid Off Grid Inverter with MPPT Solar Charge Controller HFP4850S80145 with Parallel Function
products formPRODUCTS
SRNE 5kW 48v Hybrid Off Grid inverter with Parallel Function HFP4850S80145 Sepecification | |||
Model | HFP4850S80-145 5KW | HFP4850U80-145 5KW | |
Permitted parallel number | 1~6 | 1~6 | |
Rated input voltage | 220Vac/230Vac | 110/120Vac | |
Input voltage range | (170Vac~280Vac) ±2%;(90Vac-280Vac) ±2% | (90Vac-140Vac) ±2% | |
Frequency | 50Hz/ 60Hz (auto-sensing) | ||
Overload/short circuit protection | Circuit breaker | ||
Conversion time (bypass and inverter) | 10ms (Typical value) | ||
AC reverse protection | yes | ||
Maximum bypass overload current | 30A | 40A | |
Inverting mode | |||
Output voltage waveform | Pure sine wave | ||
Rated output power(VA) | 5000 | 5000 | |
Rated output power(W) | 5000 | 5000 | |
Power factor | 1 | ||
Rated output voltage (Vac) | 230Vac | 120Vac | |
Peak power | 10000VA | 10000VA | |
Loaded motor capacity | 3HP | 3HP | |
Output short-circuit protection | Breaker | ||
Specification of bypass breaker | 40A | ||
Rated battery input voltage | 48V (minimum start voltage 44V) | ||
Battery voltage range | Undervoltage alarm/shutdown voltage/overvoltage alarm /overvoltage | ||
recovery... settable on LCD screen) | |||
Power saving mode | Load ≤50W | ||
AC charge | |||
Battery type | Lead acid or lithium battery | ||
Maximum charge current | 0-60A | 0-60A | |
Charge current error | ±3Adc | ||
Charge voltage range | 20~33Vdc | ||
Short-circuit protection | Breaker and blown fuse | ||
Breaker specification | 40A | ||
Overcharge protection | Alarm and turn off charging after 1 minute | ||
Solar charge | |||
Maximum PV opencircuit voltage | 145Vdc | ||
PV operation voltage range | 60-145Vdc | ||
MPPT voltage range | 60-115Vdc | ||
Battery voltage range | 40-60Vdc | ||
Maximum output power | 4400W | ||
Charge current range of solar energy (settable) | 80A | ||
Charge short-circuit protection | Blown fuse | ||
Wiring protection | Reverse polarity protection | ||
Hybrid charging Max charger current specifications (AC charger+PV charger) | |||
Max charger current(can be | 0-140A | 0-140A | |
set) | |||
Authentication specification | |||
Specification authentication | CE(IEC 62109-1) | CE(IEC62109-1)/CETL(UL 1741 C22.2 NO.107.1) | |
EMC authentication grade | EN61000,C2 | ||
Communication interface | USB/RS485 (WiFi/GPRS)/dry node control | ||
Dimension (L*W*D) | 426mm*322mm*124mm | ||
Weight (kg) | 10.8KG |
products DESCRIPTIONPRODUCTS
48V/5KW Off Grid Solar Inverter
Model Number: HFP4850S80-145
Max. PV Input Voltage:145Vdc
Output Voltage:230VAC
Output Frequency:50Hz/ 60Hz
Size:338*430*135mm
Weight:12 kgs
AC Charge Current:60A
Max PV solar charge current:80A