Deye SUN-15K-SG01HP3-EU-AM2 15kW Three Phase 2 MPPT Hybrid Inverter
products formPRODUCTS
Deye Solar Inverter | |||||
Model | SUN-14K-SG05LP3-EU-SM2 | SUN-15K-SG05LP3-EU-SM2 | SUN-16K-SG05LP3-EU-SM2 | SUN-18K-SG05LP3-EU-SM2 | SUN-20K-SG05LP3-EU-SM2 |
Battery Input Data | |||||
Battery Type | Lead-acid or Lithium-ion | ||||
Battery Voltage Range (V) | 40-60 | ||||
Max. Charging Current (A) | 260 | ||||
Max. Discharging Current (A) | 260 | ||||
Number of Battery Input | 1 | ||||
Charging Strategy for Li-Ion Battery | Self-adaption to BMS | ||||
PV String Input Data | |||||
Max. DC Input Power (W) | 18200 | 19500 | 20800 | 23400 | 26000 |
Max. DC Input Voltage (V) | 800 | ||||
Start-up Voltage (V) | 160 | ||||
MPPT Voltage Range (V) | 160-650 | ||||
Rated DC Input Voltage (V) | 550 | ||||
Max. Operating PV Input Current (A) | 36+20 | ||||
Max. Input Short-Circuit Current (A) | 54+30 | ||||
No.of MPPT Trackers/ | 2/2+2 | ||||
No.of String Per MPPT Tracker | |||||
AC Output Data | |||||
Rated AC Output Active Power (W) | 14000 | 15000 | 16000 | 18000 | 20000 |
Max AC Output Active Power (W) | 15400 | 16500 | 17600 | 19800 | 22000 |
Rated AC Input/Output Current (A) | 21.3/20.3 | 22.8/21.8 | 24.3/23.2 | 27.3/26.1 | 30.4/29 |
Max AC Output Current (A) | 23.4/22.4 | 25/24 | 26.7/25.6 | 30/28.7 | 33.4/31.9 |
Max. Three-phase Unbalanced Output Current (A) | 31.9/30.5 | 34.1/32.7 | 36.4/34.8 | 41/39.2 | 45.5/43.5 |
Max. Continuous AC Passthrough (A) | 70 | ||||
Peak Power (off grid) | 2 times of rated power, 10s | ||||
Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | ||||
Rated Input/Output Voltage/Range (V) | 220/380V, 230/400V 0.85Un-1.1Un | ||||
Rated Input/Output Grid Frequency/Range(Hz) | 50/45-55, 60/55-65 | ||||
Grid Connection Form | 3L+N+PE | ||||
Total Current Harmonic Distortion THDi | <3% (of nominal power) | ||||
DC Current Injection | <0.5% In | ||||
Efficiency | |||||
Max. Efficiency | 97.60% | ||||
Euro Efficiency | 97.00% | ||||
MPPT Efficiency | 99.90% | ||||
Equipment Protection | |||||
Integrated | DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection | ||||
AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection | |||||
DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring | |||||
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch | |||||
Overvoltage Load Drop Protection, Residual Current (RCD) Detection, Surge protection level | |||||
Surge Protection Level | TYPE II(DC), TYPE II(AC) | ||||
Interface | |||||
Communication Interface | WIFI, RS485, CAN | ||||
General Data | |||||
Operating Temperature Range (℃) | -40-60℃, >45℃ Derating | ||||
Permissible Ambient Humidity | 0-100% | ||||
Permissible Altitude | 3000m | ||||
Noise | ≤55 dB(A) | ||||
Ingress Protection(IP) Rating | IP 65 | ||||
Inverter Topology | Non-Isolated | ||||
Over Voltage Category | OVC II(DC), OVC III(AC) | ||||
Cabinet Size (WxHxD mm) | 456×750×266 (Excluding Connectors and Brackets) | ||||
Weight (kg) | 38 | ||||
Type of Cooling | Intelligent Air Cooling | ||||
Warranty | 5 Years/10 Years | ||||
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy | |||||
Grid Regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, | ||||
OVE-Richtlinie R25, G99, VDE-AR-N 4105 | |||||
Safety / EMC Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
products DESCRIPTIONPRODUCTS
Remotely shutdown function
Smart Monitoring Platform
Thanks to the smart monitoring platform,
Deye full series inverter products support remotely shutdown immediately when accident occurs.
Setting parameters and FW update remotely, which makes PV plant O&M easier.
Deye Inverter Features:
100% unbalanced output, each phase; Max. output up to 50% rated power
AC couple to retrofifit existing solar system
Max. 10 pcs parallel for on-grid and off-grid
operation; Support multiple batteries parallel
Max. charging/discharging current of 350A
Support storing energy from diesel generator
48V low voltage battery, transformer isolation design
6 time periods for battery charging/discharging